Determination of water balance components with high precision weighing lysimeter in Kleče

Authors

  • Vesna ZUPANC University of Ljubljana, Biotechnical Faculty, Jamnikarjeva 101, 1000 Ljubljana, Slovenia
  • Reinhard NOLZ Institute of Hydraulics and Rural Water Management, University of Natural Resources and Life Sciences, Vienna, Austria
  • Peter CEPUDER Institute of Hydraulics and Rural Water Management, University of Natural Resources and Life Sciences, Vienna, Austria
  • Branka BRAČIČ – ŽELEZNIK Drinking Water and Sewerage System Public Utility, Ljubljana, Slovenia
  • Marina PINTAR University of Ljubljana, Biotechnical Faculty, Jamnikarjeva 101, 1000 Ljubljana, Slovenia

DOI:

https://doi.org/10.14720/aas.2012.99.2.14501

Keywords:

weighing lysimeter, water balance, lysimeter station

Abstract

Components of the basic water balance equation and water balance calculation for July 2011 for weighing lysimeter on water supply pumping station in Kleče, Ljubljana the presented. Lysimeter and outflow mass measured with high precision weighing cells and precipitation as determined from changes in the mass of the lysimeter were used in calculation. Precipitation measurements in the same time resolution as the lysimeter mass measurements would be needed for correct calculation of actual evapotranspiration. In time of high plant water requirements only substantial precipitation events directly contribute to immediate groundwater recharge. The low water retention of the aquifer sediments shows susceptibility of the aquifer to ground water pollution.

Downloads

Published

26. 10. 2012

Issue

Section

Original Scientific Article

How to Cite

ZUPANC, V., NOLZ, R., CEPUDER, P., BRAČIČ – ŽELEZNIK, B., & PINTAR, M. (2012). Determination of water balance components with high precision weighing lysimeter in Kleče. Acta Agriculturae Slovenica, 99(2), 165–173. https://doi.org/10.14720/aas.2012.99.2.14501