Abstract

Knot configurations serve as the foundation for postoperative tissue repair. Loosening surgical knots during or after tying might lead to an unsuccessful suture and compromise the outcome. This investigation was car­ried out to study the mechanical properties of knotted silk sutures that are made from braided structures with three different diameters. A maximum tensile strength (33.24 N) and minimum breaking elongation (15%) of dry suture, maximum tensile strength (22.6 N) and minimum breaking elongation (13.6%) of wet suture were achieved with five throws and a diameter of 0.3 mm with surgeon’s square knot.

References

ALTMAN, Gregory H., DIAZ, Frank, JAKUBA, Caroline, CALABRO, Tara, HORAN, Rebecca L., CHEN, Jingsong, LU, Helen, RICHMOND, John, KAPLAN, David L. Silk-based biomaterials. Biomaterials, 2003, 24(3), 401–416, doi: 10.1016/S0142-9612(02)00353-8. DOI: https://doi.org/10.1016/S0142-9612(02)00353-8

ERGÜN, Selim, AKGÜN, Umut, KARAHAN, Mustafa. The effect of loop size on loop security and elongation of a knot. Orthopaedics & Traumatology: Surgery & Research, 2020, 106(1), 35–38, doi:10.1016/J.OTSR.2019.10.008. DOI: https://doi.org/10.1016/j.otsr.2019.10.008

DEBBABI, Faten, ABDESSALEM, Saber B. New approach for appreciating the surgeon’s satisfaction of braided sutures. Journal of Industrial Textiles, 2015, 46(6), 1319–1341, doi: 10.1177/1528083715622426. DOI: https://doi.org/10.1177/1528083715622426

FAULKNER, Brent C., TRIBBLE, Curtis G., THACKER, John G., RODEHEAVER, George T., EDLICH, Richard F. Knot performance of polypropylene sutures. Journal of Biomedical Materials Research, 1996, 33(3), 187–192, doi: 10.1002/(SICI)1097-4636(199623)33:3<187::AID-JBM8>3.0.CO;2-M. DOI: https://doi.org/10.1002/(SICI)1097-4636(199623)33:3<187::AID-JBM8>3.0.CO;2-M

TOMITA, N., TAMAI, S., MORIHARA, T., IKEUCHI, K., IKADA, Y. Handling characteristics of braided suture materials for tight tying. Journal of Applied Biomaterials, 1993, 4(1), 61–65, doi: 10.1002/JAB.770040108. DOI: https://doi.org/10.1002/jab.770040108

IVY, Joseph J., UNGER, James B., HURT, Jason, MUKHERJEE, Debi. The effect of number of throws on knot security with nonidentical sliding knots. American Journal of Obstetrics and Gynecology, 2004, 191(5), 1618–1620, doi: 10.1016/J.AJOG.2004.05.029. DOI: https://doi.org/10.1016/j.ajog.2004.05.029

KIM, Jin-Cheol, LEE, Yong-Keun, LIM, Bum-Soon, RHEE Sang-Hoon, YANG, Hyeong-Cheol. Comparison of tensile and knot security properties of surgical sutures. Journal of Materials Science. Materials in Medicine, 2007, 18(12), 2363–2369, doi: 10.1007/S10856-007-3114-6. DOI: https://doi.org/10.1007/s10856-007-3114-6

BAYRAKTAR, E. Karaca, HOCKENBERGER, A. Şengönül. Investigating the knot performance of silk, polyamide, polyester, and polypropylene sutures. Textile Research Journal, 2016, 71(5), 435–440, doi: 10.1177/004051750107100511. DOI: https://doi.org/10.1177/004051750107100511

HRISTOV, Krasimira, ARMSTRONG-CARROLL, Eileen, DUNN, Matt, PASTORE, Christopher, GOWAYED, Yasser. Mechanical behavior of circular hybrid braids under tensile loads. Textile Research Journal, 2016, 74(1), 20–26, doi: 10.1177/004051750407400104. DOI: https://doi.org/10.1177/004051750407400104

BEN ABDESSALEM, Saber, DEBBABI, Faten, JEDDA, Hanen, ELMARZOUGUI, Saber, MOKHTAR, Sofiene. Tensile and knot performance of polyester braided sutures. Textile Research Journal, 2009, 79(3), 247–252, doi: 10.1177/0040517508094090. DOI: https://doi.org/10.1177/0040517508094090

IM, Jung Nam, KIM, Jeong Kyung, KIM, Hyun Kyoon, LEE, Kuen Yong, PARK, Won Ho. Effect of tying conditions on the knot security of suture materials. Journal of Applied Polymer Science, 2008, 109(2), 918–922, doi: 10.1002/APP.28109. DOI: https://doi.org/10.1002/app.28109

SILVER, E., WU, R., GRADY, J., SONG, L. Knot security-how is it affected by suture technique, material, size, and number of throws? Journal of Oral and Maxillofacial Surgery, 2016, 74(7), 1304–1312, doi: 10.1016/j.joms.2016.02.004. DOI: https://doi.org/10.1016/j.joms.2016.02.004

WASEEM, Muhammad, SALAH, Bashir, HABIB, Tufail, SALEEM, Waqas, ABAS, Muhammad, KHAN, Razaullah, GHANI, Usman, SIDDIQI, Muftooh Ur Rehman. Multi-response optimization of tensile creep behavior of PLA 3D printed parts using categorical response surface methodology. Polymers, 2020, 12(12), 1–16, doi: 10.3390/POLYM12122962. DOI: https://doi.org/10.3390/polym12122962

ZIMMER, Christopher A., THACKER, John G., POWELL, David M., BELLIAN, Kenneth T., BECKER, Daniel G., RODEHEAVER, George T., EDLICH, Richard F. Influence of knot configuration and tying technique on the mechanical performance of sutures. Journal of Emergency Medicine, 1991, 9(3), 107–113, doi: 10.1016/0736-4679(91)90313-5. DOI: https://doi.org/10.1016/0736-4679(91)90313-5

LIVERMORE, Ryan W., CHONG, Alexander C.M., PROHASKA, Daniel J., COOKE, Francis W., JONES, Teresa L. Knot security, loop security, and elongation of braided polyblend sutures used for arthroscopic knots. American Journal of Orthopedics (Belle Mead, NJ), 2010, 39(12), 569–576.

MISHRA, Dev K., CANNON, W. Dilworth, LUCAS, Duncan J., BELZER, John P. Elongation of arthroscopically tied knots. American Journal of Sports Medicine, 1997, 25(1), 113–117, doi: 10.1177/036354659702500122. DOI: https://doi.org/10.1177/036354659702500122

Downloads

Published

2023-08-28

How to Cite

Natarajan, S., Ramesh Babu, V., Ariharasudhan, S., Chandrasekaran, P., & Sundaresan, S. (2023). Investigating the Effect of Knot Configuration and Suture Diameter on the Knot Performance of Silk Sutures . Tekstilec, 66, 199–210. https://doi.org/10.14502/tekstilec.66.2023028

Issue

Section

Scientific article